I. Introduction
Vehicle position detection and communication system aims at solving two problems: industrial rail locomotive position detection, and data communication between ground control room and locomotives; system consists of two parts: position detection and data communication.
The position detection part is used to detect location information, the address generator sends carrier signal to encoded cables, the antenna box receives induction signal encoded cables then sends it to vehicle address detector for processing signal, and the internal MCU calculates the location of locomotive. Since the type of detection method obtains position information on the locomotive, it is particularly suitable to a work site where multiple vehicles work simultaneously.
The communication part is used to communicate data between central control room and locomotives, the ground communicator modulates the central control room data into carrier signal then sends it to encoded cables, and then the vehicle communication antenna box receives signal and sends it to vehicle communicator for modulating data. Similarly, vehicle communicator modulates locomotive data into carrier signal and sends it to communication antenna box, the encoded cables receive signal and send it to ground communicator for modulating data, so as to realize data communication.
II. Function
Real-time detection of locomotive position.
Real-time communication between locomotive and ground control room.
III. Structure
IV. Advantages
?position detection
IV. Application
l positi
(1)Communication interface: RS-485, industrial Ethernet, Profibus-DP、ProfiNET
(2)Baud rate: 9600bit/S
(3)Verification mode: even parity check+ Vertical and horizontal redundancy check
(4)Address detection resolution: 2mm
(5)Address detection rate: 30 times/s
?data communication
(1)Communication interface: RS-485
(2)Baud rate: 2400bit/S-9600bit/S
(3)Verification mode: even parity check+ Vertical and horizontal redundancy check
(4)Communication cycle: 200ms
?Safety
Dielectric strength: connect between power supply terminal and shell and bear AC1500V high voltage for more than 1 minute, no break down. Leak current <3.5mA.
?Reliability
System is able work in the environment of -25 ° C ~ 85 ° C for a long time; resistance to industrial pollution, resistance to co-channel interference, vibration and impact resistance; be able to adapt to harsh industrial environments.
Mean time between failures is greater than 12 months.
l positio
l positio
On the basis of intelligent control platform of coking integration, the system consists of desulfuration subsystem, amm..
DetailsTaking “balanced the gas transmission” as the core, the intelligent pressure control system for gas collecting process ..
DetailsDuring temping, traditionally the altimetry of coking coal cake in temping station is inspected visually by experienced..
DetailsCoke oven unmanned duty system is not only a strategic choice for visionary coking enterprises, but also a realistic tr..
Detailscopyright Hunan Qianmeng Industrial Intelligent System address:28 Kangwang Industrial Park, Yueyang record number:湘ICP備20000218號-1business license
Technical Support:Competition network